Venus Versa™

    Vs.

    Multi-Treatment Platform.

    A versatile multi-application platform that provides the most popular, non-invasive aesthetic procedures, including photorejuvenation/photofacial, acne treatment, hair removal, skin resurfacing, body contouring, cellulite reduction, skin tightening, and wrinkle reduction.

    Venus Versa™ Device

    TriBella™

    TriBella™ is a complete skin rejuvenation treatment, which combines three effective, unique technologies into one treatment protocol to improve tone, tightness, and texture. Exclusively available with our Venus Versa™ system, TriBella™ treatments give clients a more youthful appearance.

    Target Tone, Texture, & Tightness

    Skin Resurfacing with NanoFractional Radio Frequency

    The Venus Viva™ MD applicator is is a highly customizable skin resurfacing technology with low downtime and is safe for all Fitzpatrick skin types.

    • MORE
      • NanoFractional skin resurfacing allows the operator to customize ablation and coagulation settings. Radio frequency energy is delivered into the skin, creating micro-channels surrounded by intact tissue, which promote faster wound healing, little-to-no downtime, and reduces the risk of post-inflammatory hyperpigmentation (PIH).
      • SmartScan™ technology uses a unique algorithm and pattern selection technology that enables the operator to generate customized patterns for maximum flexibility and patient safety.
      • Improves the appearance of textural skin conditions such as scars (including acne scars), rosacea, striae, uneven skin texture, enlarged pores, dyschromia, and pigmentation.

    Intense Pulsed Light (IPL) Technology with SmartPulse™

    The IPL photorejuvenation, acne treatment, and hair removal applicators include innovative SmartPulse™ technology to ensure comfortable, precise, and consistent energy delivery through advanced pulse optimization. Real-time cooling system monitors the light-guide temperature 1,000 times a second for unparalleled patient safety and comfort.

    • MORE
      • Photorejuvenation/Photofacial: Effectively target & treat vascular and pigmented lesions on the skin.
      • Hair Removal: Efficiently target melanin in the hair shaft for comfortable hair removal treatments.
      • Dual-light-guide Acne Treatment: Innovative dual-light-guide technology: blue light targets porphyrin caused by Propionibacterium Acnes bacteria, leading to the destruction of the P. Acnes bacteria, while the red light promotes faster healing and effectively decreases inflammation.

    Multi-Polar Radio Frequency

    Body contouring, cellulite reduction, skin tightening, and wrinkle reduction:

    Unique combination of Multi-Polar Radio Frequency (RF) and Pulsed Electro Magnetic Fields (PEMF).

    • MORE
      • With the capabilities of multi-polar radio frequency applicators, the Venus Versa™ uses a complex algorithm to deliver homogeneous energy and volumetric heating to multiple tissue depths, allowing for quick and safe buildup of heat and easy maintenance of therapeutic temperature throughout the treatment
      • Effect of Multi-Polar RF is enhanced by PEMF, a non-thermal mechanism emitted through the applicator’s electrodes
      • Through synergistic (MP)², RF heats and directly stimulates fibroblasts, while PEMF is known to promote angiogenesis and induce fibroblast proliferation through release of the growth factor FGF-2, resulting in increased collagen synthesis²
      • (MP)² is therefore effective in collagen remodeling for body contouring via skin tightening, cellulite reduction, and wrinkle reduction, and the creation of new capillaries for renewal of blood supply.

    Venus Versa™ offers three unique technologies: Intense Pulsed Light (IPL) with SmartPulse™, NanoFractional Radio Frequency with SmartScan™, and Venus proprietary (MP) 2 technology (Multi-Polar Radio Frequency + Pulsed Electro Magnetic Fields).


    With the ability to meet today’s most in demand aesthetic treatments the Venus Versa™ is a sound investment for any clinic looking to expand its offerings with one workstation. Our versatile multifunction machine allows you to offer a variety of services, increase patient demand and positively impact your ROI – all factors that will help your practice thrive for years to come.

    TECHNOLOGY

    Photorejuvenation

    Photorejuvenation treatment

    The photorejuvenation protocol in the TriBella™ treatment corrects benign pigmented lesions and benign vascular lesions.

    Wrinkle Reduction

    Enhances collagen production to reduce the appearance of skin laxity, wrinkles and rhytides.

    Wrinkle Reduction treatment

    Skin Resurfacing

    Skin Resurfacing treatment

    Improves the appearance of textural skin conditions such as scars (including acne scars), rosacea, striae, uneven skin texture, enlarged pores, dyschromia, and pigmentation.

    The Results Speak for Themselves

    All of the before-and-after photos for our aesthetic treatments are from certified Venus providers showcasing real patient results. Images are never edited or altered.

    Tech Specs

    Technology
    • AC DUAL IPL APPLICATOR

      Wavelength - 415-480 nm, 630-950 nm


      Optical Fluence - 5-25 J/cm2


      Pulse Duration - 10-20 ms


      Spot Size - 10 mm x 30 mm


      Pulse Repetition Rate - Up to 3 Hz

    • NANOFRACTIONAL RF™ APPLICATOR

      Output RF Frequency - 0.46 MHz


      Fuse -3.15A, 250V


      Max. Output Energy - 62 mJ/pin


      Ablation Depth - Up to 500 microns


      Number of Pins - Up to 160

    • DIAMONDPOLAR™ & OCTIPOLAR™ APPLICATORS

      Output RF Frequency - 1MHz


      RF Output Power- 0-150 Watts


      Number of (MP)2 Synthesizers - Up to 8 


      Magnetic Pulse Frequency - 15 Hz


      Pulsed Magnetic Field - Up to 15 Gauss



    • Device

      Electrical Requirements - 100-240 VAC ,12.5A, 50-60Hz, Single Phase


      Dimensions - 55 cm x 65 cm x 110 cm / 21.7 in x 25.6 in x 43.3 in (D x W x H)


      Weight - 35 Kg / 77.2 lb

    • SR515 / SR580 IPL APPLICATORS

      Wavelength - 515-950 nm, 580-950 nm


      Optical Fluence - 5-25 J/cm2


      Pulse Duration - 10-20 ms


      Spot Size - 10 mm x 30 mm


      Pulse Repetition Rate - Up to 3 Hz

    • HR650 (XL) / HR690 (XL) IPL APPLICATORS

      Wavelength - 650-950 nm, 690-950 nm 


      Optical Fluence - 5-20 J/cm2


      Pulse Duration - 20-50 ms 


      Spot Size - 10 mm x 30 mm (XL: 20 mm x 30 mm)


      Pulse Repetition Rate - Up to 3 Hz

    Venus Versa Device
    • “The Venus Versa™ platform technology provides the best combination of all. With about 10 different handpieces, each for different procedures, I, as the physician, can choose which combination is best suited to my practice, my patients. I selected Venus Versa™ with Intense Pulsed Light for hair removal and skin rejuvenation.”

      Robert M. Freund, MD

    Speak To An Expert

    To book a consultation or a demo, please contact us by clicking the button below and a representative will reach out to you directly.

    INDICATIONS FOR USE:


     *Venus Versa™ has CE Mark as a multi-application device intended to be used in aesthetic and cosmetic procedures. The SR515 and SR580 applicators have CE Mark for the treatment of benign pigmented epidermal and cutaneous lesions and treatment of benign cutaneous vascular lesions. The HR650/HR650XL and HR690/HR690XL applicators have CE Mark for the removal of unwanted hair and to effect stable long-term or permanent hair reduction for Fitzpatrick skin types I-IV. The AC Dual applicator has CE Mark for the treatment of acne vulgaris. The DiamondPolar™ applicator has CE Mark for non-invasive treatment of moderate to severe facial wrinkles and rhytides in Fitzpatrick skin types I-IV. The OctiPolar™ applicators on the Venus Versa™ system has CE Mark for temporary body contouring via skin tightening, circumferential reduction, and cellulite reduction. The NanoFractional RF™ (Viva) applicator has CE Mark for dermatological procedures requiring ablation and resurfacing of the skin.


    REFERENCES:


    1. Ponqgsrihadulchai N, Chalermchai T, Ophaswongse S, Pongsawat S, Udompataikul M. An efficacy and safety of nanofractional radiofrequency for the treatment of striae alba. J Cosmet Dermatol. 2016; 1-7.

    2. Callaghan, M. J., Chang, E. I., Seiser, N., Aarabi, S., Ghali, S., Kinnucan, E. R., . . . Gurtner, G. C. (2008). Pulsed Electromagnetic Fields Accelerate Normal and Diabetic Wound Healing by Increasing Endogenous FGF-2 Release. Plastic and Reconstructive Surgery, 121(1), 130-141. doi:10.1097/01.prs.0000293761.27219.84

    3. Soda, A., Ikehara, T., Kinouchi, Y., & Yoshizaki, K. (2008). Effect of exposure to an extremely low frequency-electromagnetic field on the cellular collagen with respect to signaling pathways in osteoblast-like cells. The Journal of Medical Investigation, 55 3-4, 267-78.

    Share by: